ANNEX C
SEACOAST SEARCHLIGHTS
1. General. Areas of illumination and location of harbor
defense searchlights are shown on Exhibit No. 1C.
2. Searchlight Control.
a. The initial control of all searchlights is under the
Harbor Defense Commander.
b. The first phase of searchlight control will consist of
the searching of water areas and the use of barrier lights until
targets are identified. This phase may occur when lights are
under the control of Harbor Defense Searchlight Officer or under
the Fort Searchlight Officers.
c. The second phase of searchlight control, that is the
use of lights as illuminating lights, will, when control has
been released to the Subordinate Commanders, be the responsi-
bility of that commander. Necessary coordination between sub-
ordinate units will be efected by the Harbor Defense Search-
light Officer and respectively Fort Searchlight Officers.
3. Tabulation of Searchlights.
| Tac- tical No. | Site No. | Coordinates | Type of S/L | Type of Emplacement | HI | Ex- hibit No. |
| 1 | 1A Narrow Cape | X 43,167.92 Y 20,684.94 | 60" AA | Splinter-proof dug-in & backfilled | 180 ft. | 20B |
| 2 | 1A Narrow Cape | X 43,521.38 Y 20,766.70 | 60" AA | Splinter-proof dug-in & backfilled | 180 ft. | 20B |
| 3 | 1 Soquel Point | X 52,063.47 Y 37,173.62 | 60" AA | Splinter-proof dug-in & backfilled | 173 ft. | 30B |
| 4 | 1 Soquel Point | X 52,144.11 Y 37,177.58 | 60" AA | Splinter-proof dug-in & backfilled | 173 ft. | 30B |
| 5 | 3 South Cape | X 55,680.37 Y 44,156.84 | 60" AA | Splinter-proof dug-in & backfilled | 100 ft. | 45B |
| 6 | 3 South Cape | X 55,692.16 Y 44,182.61 | 60" AA | Splinter-proof dug-in & backfilled | 100 ft. | 45B |
| 7 | 3 South Cape | X 55,649.88 Y 44,852.61 | 60" AA | Splinter-proof dug-in & backfilled | 106 ft. | 27B |
| 8 | 3 Bald Hill | X 54,967.87 Y 45,228.57 | 60" AA | Splinter-proof dug-in & backfilled | 95 ft. | 46B |
| 9 | 6 Midway Point | X 48,275.15 Y 45,667.14 | 60" AA | Splinter-proof dug-in & backfilled | 50 ft. | 47B |
| 10 | 6 Midway Point | X 48,202.01 Y 45,666.52 | 60" AA | Splinter-proof dug-in & backfilled | 63 ft. | 47B |
| Tac- tical No. | Site No. | Coordinates | Type of S/L | Type of Emplacement | HI | Ex- hibit No. |
| 11 | 8A Puffin Island | X 37,625.32 Y 61,154.00 | 60" spread beam | Splinter-proof dug-in & backfilled | 32 ft. | 43B |
| 12 | 9 Gibson Cove | X 36,586.47 Y 64,216.57 | 60" AA | Splinter-proof dug-in & backfilled | 260 ft. | 48B |
| 13 | 9 Gibson Cove | X 36,669.49 Y 64,251.89 | 60" AA | Splinter-proof dug-in & backfilled | 2-- ft. | 48B |
| 14 | 10 Pyramid Point | X 45,873.81 Y 60,697.24 | 60" AA | Splinter-proof dug-in & backfilled | 160 ft. | 49B |
| 15 | 10 Burt Point | X 46,320.71 Y 60,483.24 | 60" AA | Splinter-proof dug-in & backfilled | 100 ft. | 36B |
| 16 | 13 North Cape | X 51,721.60 Y 64,397.95 | 60" AA | Splinter-proof dug-in & backfilled | 105 ft. | 39B |
| 17 | 13 North Cape | X 51,723.40 Y 64,634.45 | 60" AA | Splinter-proof dug-in & backfilled | 135 ft. | 39B |
| 18 | 14 Point Head | X 49,276.40 Y 65,371.78 | 60" AA | Splinter-proof dug-in & backfilled | 175ft. | 37B |
| 19 | 15 Spruce Cape | X 44,408.10 Y 68,922.10 | 60" spread beam | Splinter-proof dug-in & backfilled | 80 ft. | 44B |
| 20 | 15 Spruce Cape | X 44,719.53 Y 69,360.69 | 60" AA | Splinter-proof dug-in & backfilled | 34 ft. | 40B |
| 21 | 16A Piedmont Point | X 43,427.32 Y 70,754.44 | 60" AA | Splinter-proof dug-in & backfilled | 78 ft. | 42B |
| 22 | 16 Miller Point | X 42,772.51 Y 71,173.10 | 60" AA | Splinter-proof dug-in & backfilled | 125 ft. | 41B |
| 23 | 17 Spruce Island | X 44,896.49 Y 80,780.01 | 60" AA | Splinter-proof dug-in & backfilled | 30 ft. | 50B |
| 24 | 17 Spruce Island | X 44,831.82 Y 80,930.50 | 60" AA | Splinter-proof dug-in & backfilled | 35 ft. | 50B |
| 25 | 18 Kizhuyak Point | X 25,051.00 Y 81,266.66 | 60" AA | Wood Frame Cottage type | 85 ft. | 22B |
| 26 | 18 Kizhuyak Point | X 24,688.66 Y 81,023.33 | 60" AA | Wood Frame Cottage type | 115 ft. | 22B |
| S/L No. | DEC No. | DEC Coordinates | Type of Power Plant | S/L on Hand | S/L to be Sup- plied | DEC on Hand | DEC to be Sup- plied |
| 1 | 1 | X 43,186.36 Y 20,684.93 | 16.2 KW SK-93 | 1 | 0 | 1 | 0 |
| 2 | 2 | X 43,529.00 Y 20,742.71 | 16.2 KW SK-93 | 1 | 0 | 1 | 0 |
| 3 | 3 | X 52,150.48 Y 37,206.47 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 4 | 4 | Combined with No. 3 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 5 | 5 | Combined with No. 6 | 16.2 KW SK-93 | 1 | 0 | 1 | 0 |
| 6 | 6 | X 55,843.69 Y 44,384.63 | 16.2 KW SK-93 | 1 | 0 | 1 | 0 |
| 7 | 7 | X 55,742.09 Y 44,835.15 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 8 | 8 | X 54,915.02 Y 45,203.71 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 9 | 9 | Combined with No. 10 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 10 | 10 | X 52,150.48 Y 37,206.47 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 11 | 11 | X 37,556.50 Y 61,156.30 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 12 | 12 | X 36,539.06 Y 64,154.53 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 13 | 13 | X 36,614.70 Y 64,225.85 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 14 | 14 | X 45,885.77 Y 60,729.60 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 15 | 15 | X 46,379.54 Y 60,534.60 | 16.2 KW GT-1501 | 1 | 0 | 1 | 0 |
| 16 | 16 | X 51,756.76 Y 64,466.82 | 16.2 KW GT-1501 | 1 | 0 | 1 | 0 |
| 17 | 17 | X 51,774.66 Y 64,609.66 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 18 | 18 | X 49,318.08 Y 65,356.14 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 19 | 19 | X 44,455.30 Y 69,016.16 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 20 | 20 | X 44,775.31 Y 69,432.32 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 21 | 21 | X 43,379.43 Y 70,819.83 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| S/L No. | DEC No. | DEC Coordinates | Type of Power Plant | S/L on Hand | S/L to be Sup- plied | DEC on Hand | DEC to be Sup- plied |
| 22 | 22 | X 42,823.73 Y 71,201.48 | 16 KW GT-1508 | 1 | 0 | 1 | 0 |
| 23 | 23 | X 44,894.83 Y 80,710.68 | 16.2 KW SK-93 | 1 | 0 | 1 | 0 |
| 24 | 24 | X 44,869.15 Y 80,915.17 | 16.2 KW SK-93 | 1 | 0 | 1 | 0 |
| 25 | 25 | X 25,035.00 Y 81,255.00 | 16.2 KW SK-93 | 1 | 0 | 1 | 0 |
| 26 | 26 | X 24,673.40 Y 81,010.00 | 16.2 KW SK-93 TOTALS | 1 26 | 0 0 | 1 26 | 0 0 |
| Location | No. & Type of Shelters |
| Site 1 - Soquel Point | 1 wood frame 16' x 16' |
| Site 1A - Narrow Cape | 1 wood frame 16' x 16' |
| Site 3 - Cape Chiniak | 1 wood frame 16' x 16' |
| Site 4 - St. Peters Head | 1 wood frame 16' x 16' |
| Site 8 - Buskin Hill | 1 wood frame 16' x 16' |
| Site 8A - Puffin Island | 1 wood frame 16' x 16' |
| Site 9 - Gibson Cove | 1 wood frame 16' x 16' |
| Site 12 - Castle Bluffs | 1 Quonset hut 16' x 36'
1 wood frame 16' x 16' |
| Site 15 - Spruce Cape | 1 wood frame 16' x 16' |
| Site 16 - Miller Point | 1 Quonset hut 16' x 36'
1 wood frame 16' x 16' |
| Site 17 - Spruce Island | 1 wood frame 16' x 16' |
| Site 18 - Kizhuyak Point | 1 wood frame 16' x 16' |