ANNEX  C

                    SEACOAST SEARCHLIGHTS

    1.  General.  Areas of illumination and location of harbor
defense searchlights are shown on Exhibit No. 1C.
    
    2.  Searchlight Control.

        a.  The initial control of all searchlights is under the
Harbor Defense Commander.

        b.  The first phase of searchlight control will consist of
the searching of water areas and the use of barrier lights until
targets are identified.  This phase may occur when lights are
under the control of Harbor Defense Searchlight Officer or under 
the Fort Searchlight Officers.

       c.  The second phase of searchlight control, that is the
use of lights as illuminating lights, will, when control has
been released to the Subordinate Commanders, be the responsi-
bility of that commander.  Necessary coordination between sub-
ordinate units will be efected by the Harbor Defense Search-
light Officer and respectively Fort Searchlight Officers.

    3.  Tabulation of Searchlights.

Tac-
tical
No.
Site
No.
Coordinates Type
of
S/L
Type
of
Emplacement
HI Ex-
hibit
No.
1 1A
Narrow
Cape
X 43,167.92
Y 20,684.94
60" AA Splinter-proof
dug-in &
backfilled
180 ft. 20B
2 1A
Narrow
Cape
X 43,521.38
Y 20,766.70
60" AA Splinter-proof
dug-in &
backfilled
180 ft. 20B
3 1
Soquel
Point
X 52,063.47
Y 37,173.62
60" AA Splinter-proof
dug-in &
backfilled
173 ft. 30B
4 1
Soquel
Point
X 52,144.11
Y 37,177.58
60" AA Splinter-proof
dug-in &
backfilled
173 ft. 30B
5 3
South
Cape
X 55,680.37
Y 44,156.84
60" AA Splinter-proof
dug-in &
backfilled
100 ft. 45B
6 3
South
Cape
X 55,692.16
Y 44,182.61
60" AA Splinter-proof
dug-in &
backfilled
100 ft. 45B
7 3
South
Cape
X 55,649.88
Y 44,852.61
60" AA Splinter-proof
dug-in &
backfilled
106 ft. 27B
8 3
Bald
Hill
X 54,967.87
Y 45,228.57
60" AA Splinter-proof
dug-in &
backfilled
95 ft. 46B
9 6
Midway
Point
X 48,275.15
Y 45,667.14
60" AA Splinter-proof
dug-in &
backfilled
50 ft. 47B
10 6
Midway
Point
X 48,202.01
Y 45,666.52
60" AA Splinter-proof
dug-in &
backfilled
63 ft. 47B
Par. 3 (Cont.)
Tac-
tical
No.
Site
No.
Coordinates Type
of
S/L
Type
of
Emplacement
HI Ex-
hibit
No.
11 8A
Puffin
Island
X 37,625.32
Y 61,154.00
60"
spread
beam
Splinter-proof
dug-in &
backfilled
32 ft. 43B
12 9
Gibson
Cove
X 36,586.47
Y 64,216.57
60" AA Splinter-proof
dug-in &
backfilled
260 ft. 48B
13 9
Gibson
Cove
X 36,669.49
Y 64,251.89
60" AA Splinter-proof
dug-in &
backfilled
2-- ft. 48B
14 10
Pyramid
Point
X 45,873.81
Y 60,697.24
60" AA Splinter-proof
dug-in &
backfilled
160 ft. 49B
15 10
Burt
Point
X 46,320.71
Y 60,483.24
60" AA Splinter-proof
dug-in &
backfilled
100 ft. 36B
16 13
North
Cape
X 51,721.60
Y 64,397.95
60" AA Splinter-proof
dug-in &
backfilled
105 ft. 39B
17 13
North
Cape
X 51,723.40
Y 64,634.45
60" AA Splinter-proof
dug-in &
backfilled
135 ft. 39B
18 14
Point
Head
X 49,276.40
Y 65,371.78
60" AA Splinter-proof
dug-in &
backfilled
175ft. 37B
19 15
Spruce
Cape
X 44,408.10
Y 68,922.10
60" spread
beam
Splinter-proof
dug-in &
backfilled
80 ft. 44B
20 15
Spruce
Cape
X 44,719.53
Y 69,360.69
60" AA Splinter-proof
dug-in &
backfilled
34 ft. 40B
21 16A
Piedmont
Point
X 43,427.32
Y 70,754.44
60" AA Splinter-proof
dug-in &
backfilled
78 ft. 42B
22 16
Miller
Point
X 42,772.51
Y 71,173.10
60" AA Splinter-proof
dug-in &
backfilled
125 ft. 41B
23 17
Spruce
Island
X 44,896.49
Y 80,780.01
60" AA Splinter-proof
dug-in &
backfilled
30 ft. 50B
24 17
Spruce
Island
X 44,831.82
Y 80,930.50
60" AA Splinter-proof
dug-in &
backfilled
35 ft. 50B
25 18
Kizhuyak
Point
X 25,051.00
Y 81,266.66
60" AA Wood Frame
Cottage
type
85 ft. 22B
26 18
Kizhuyak
Point
X 24,688.66
Y 81,023.33
60" AA Wood Frame
Cottage
type
115 ft. 22B
Par. 3 (Cont.)
S/L
No.
DEC
No.
DEC
Coordinates
Type of
Power
Plant
S/L
on
Hand
S/L to
be Sup-
plied
DEC
on
Hand
DEC to
be Sup-
plied
1 1 X 43,186.36
Y 20,684.93
16.2 KW
SK-93
1 0 1 0
2 2 X 43,529.00
Y 20,742.71
16.2 KW
SK-93
1 0 1 0
3 3 X 52,150.48
Y 37,206.47
16 KW
GT-1508
1 0 1 0
4 4 Combined
with No. 3
16 KW
GT-1508
1 0 1 0
5 5 Combined
with No. 6
16.2 KW
SK-93
1 0 1 0
6 6 X 55,843.69
Y 44,384.63
16.2 KW
SK-93
1 0 1 0
7 7 X 55,742.09
Y 44,835.15
16 KW
GT-1508
1 0 1 0
8 8 X 54,915.02
Y 45,203.71
16 KW
GT-1508
1 0 1 0
9 9 Combined
with No. 10
16 KW
GT-1508
1 0 1 0
10 10 X 52,150.48
Y 37,206.47
16 KW
GT-1508
1 0 1 0
11 11 X 37,556.50
Y 61,156.30
16 KW
GT-1508
1 0 1 0
12 12 X 36,539.06
Y 64,154.53
16 KW
GT-1508
1 0 1 0
13 13 X 36,614.70
Y 64,225.85
16 KW
GT-1508
1 0 1 0
14 14 X 45,885.77
Y 60,729.60
16 KW
GT-1508
1 0 1 0
15 15 X 46,379.54
Y 60,534.60
16.2 KW
GT-1501
1 0 1 0
16 16 X 51,756.76
Y 64,466.82
16.2 KW
GT-1501
1 0 1 0
17 17 X 51,774.66
Y 64,609.66
16 KW
GT-1508
1 0 1 0
18 18 X 49,318.08
Y 65,356.14
16 KW
GT-1508
1 0 1 0
19 19 X 44,455.30
Y 69,016.16
16 KW
GT-1508
1 0 1 0
20 20 X 44,775.31
Y 69,432.32
16 KW
GT-1508
1 0 1 0
21 21 X 43,379.43
Y 70,819.83
16 KW
GT-1508
1 0 1 0
Par. 3 (Cont.)
S/L
No.
DEC
No.
DEC
Coordinates
Type of
Power
Plant
S/L
on
Hand
S/L to
be Sup-
plied
DEC
on
Hand
DEC to
be Sup-
plied
22 22 X 42,823.73
Y 71,201.48
16 KW
GT-1508
1 0 1 0
23 23 X 44,894.83
Y 80,710.68
16.2 KW
SK-93
1 0 1 0
24 24 X 44,869.15
Y 80,915.17
16.2 KW
SK-93
1 0 1 0
25 25 X 25,035.00
Y 81,255.00
16.2 KW
SK-93
1 0 1 0
26 26 X 24,673.40
Y 81,010.00
16.2 KW
SK-93
 
TOTALS
1


26
0


0
1


26
0


0
4. Shelters for Searchlights. a. Shelters (other than these at tactical positions) for storage and for use as searchlight meintenance buildings.
Location No. & Type of Shelters
   Site 1  - Soquel Point 1 wood frame   16' x 16'
   Site 1A - Narrow Cape 1 wood frame   16' x 16'
   Site 3  - Cape Chiniak 1 wood frame   16' x 16'
   Site 4  - St. Peters Head 1 wood frame   16' x 16'
   Site 8  - Buskin Hill 1 wood frame   16' x 16'
   Site 8A - Puffin Island 1 wood frame   16' x 16'
   Site 9  - Gibson Cove 1 wood frame   16' x 16'
   Site 12 - Castle Bluffs 1 Quonset hut  16' x 36'
1 wood frame   16' x 16'
   Site 15 - Spruce Cape 1 wood frame   16' x 16'
   Site 16 - Miller Point 1 Quonset hut  16' x 36'
1 wood frame   16' x 16'
   Site 17 - Spruce Island 1 wood frame   16' x 16'
   Site 18 - Kizhuyak Point 1 wood frame   16' x 16'
5. Construction Status of Searchlight Positions. a. All searchlight and power plant shelters, DEC shelters and searchlight storage and maintenance buildings have been com- pleted. b. For general location of searchlights see Exhibit No. 2A. c. For accessible roads see Exhibits listed in Par. 3, Annex C. 6. No land acquisition is needed for searchlight positions. For required lands see par. 9, Annex A.